Testing Capabilities

All HK Series products undergo qualification and acceptance testing per GJB 360B-2009 and applicable detail specifications. The following test capabilities are available for customer verification and custom qualification programs.

Environmental Testing

TestStandardCapability
Sinusoidal VibrationGJB 360B-200910–2000 Hz, 15G, 3 axes
Random VibrationGJB 360B-2009 (Grade D)0.04–1.0 g²/Hz, 119.5 m/s² Grms
ShockGJB 360B-2009100G, 11ms half-sine
Thermal CyclingGJB 360B-2009-184°C to +260°C
HumidityGJB 360B-200910 days
Salt SprayGJB 360B-200996 hours
AltitudeGJB 360B-2009Up to 70,000 ft equivalent

Hermetic Seal Testing

Helium mass spectrometer leak detection per GJB 360B-2009:

  • Acceptance criterion: ≤1×10⁻³ Pa·cm³/s
  • Test method: Helium tracer gas + mass spectrometer tuned to mass 4
  • Sample plan: Per applicable detail specification

Electrical Testing

  • Contact resistance: <50mΩ (measured by 4-wire Kelvin method)
  • Dielectric withstanding voltage: Per product specification
  • Insulation resistance: >1000MΩ at 500V DC
  • Contact bounce: <10μs at rated load

EMI/RFI Testing (for Shielded Models)

Available for KWQMY2-3AT series per GJB 151B / MIL-STD-461

Custom Test Programs

Customers may request specific test programs beyond standard qualification. Contact engineering for test plan development and pricing.